K3MA-J-A2 24VAC/VDC Tech Specifications

Category Panel Meters
Manufacturer Omron
Factory Lead Time 6 Weeks
Mounting Type Panel Mount
Weight 0.441lb 200.03g
Published 2001
Series K3MA-J
Operating Temperature -10°C~55°C
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Type Process Meter
Voltage - Supply 24VAC/DC
Ingress Protection IP66 - Dust Tight, Water Resistant
Termination Style Screw Terminal
Output Type Relay (2)
Panel Cutout Dimensions Rectangular - 92.00mm x 45.00mm
Display Type LCD - Dual Color Characters, Backlight
Number of Characters Per Row 5Characters Per Rows
Measuring Range 0 ~ 20mA, ±10VDC
Display Characters - Height 0.560 14.20mm
RoHS Status RoHS Compliant
Select at least one checkbox above to show similar products in this category.
View Similar

K3MA-J-A2 24VAC/VDC Documents

Download datasheets and manufacturer documentation for   K3MA-J-A2 24VAC/VDC

K3MA-J-A2 24VAC/VDC brand manufacturers: Omron Automation and Safety, Elecinsight stock, K3MA-J-A2 24VAC/VDC reference price.Omron Automation and Safety. K3MA-J-A2 24VAC/VDC parameters, K3MA-J-A2 24VAC/VDC Datasheet PDF and pin diagram description download.You can use the K3MA-J-A2 24VAC/VDC Panel Meters, DSP Datesheet PDF, find K3MA-J-A2 24VAC/VDC pin diagram and circuit diagram and usage method of function,K3MA-J-A2 24VAC/VDC electronics tutorials.You can download from the Elecinsight.