CSS150-36 Tech Specifications

Category AC DC Converters
Manufacturer TDK Lambda
Factory Lead Time 13 Weeks
Mount Chassis Mount, Panel
Mounting Type Chassis Mount
Number of Pins 10Pins
Weight 340.194277g
Operating Temperature 0°C~70°C With Derating
Series CSS150 (150W)
Published 2009
Size / Dimension 5.00Lx3.00W x 1.30 H 127.0mmx76.2mmx33.0mm
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Number of Terminations 10Terminations
Type Open Frame
Applications Medical
Power (Watts) 100W 150W Forced Air
Additional Feature REMOTE SHUTDOWN
Power Rating 150W
Max Power Dissipation 100W
Terminal Position UNSPECIFIED
Terminal Form UNSPECIFIED
Number of Functions 1Function
Depth 76.2mm
Number of Outputs 1Output
Approval Agency CE
Efficiency 89%
Voltage - Isolation 4kV
Output Voltage 36V
Max Output Current 2.8A
Input Voltage-Nom 115V
Trim/Adjustable Output YES
Max Current Rating 1.7A
Output Current 4.2A
Output Power 100W
Protections OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE
Current - Output 1 4.2A
Max Output Power 100W
Minimum Load Required No
Nominal Output Voltage 36V
Features DC Input Capable, Remote On/Off, Universal Input
Height 30mm
REACH SVHC No SVHC
RoHS Status RoHS Compliant
Lead Free Lead Free
Select at least one checkbox above to show similar products in this category.
View Similar

CSS150-36 Documents

Download datasheets and manufacturer documentation for   CSS150-36

CSS150-36 brand manufacturers: TDK-Lambda Americas Inc., Elecinsight stock, CSS150-36 reference price.TDK-Lambda Americas Inc.. CSS150-36 parameters, CSS150-36 Datasheet PDF and pin diagram description download.You can use the CSS150-36 AC DC Converters, DSP Datesheet PDF, find CSS150-36 pin diagram and circuit diagram and usage method of function,CSS150-36 electronics tutorials.You can download from the Elecinsight.